OPERATING CONDITIONS:
Pumped liquid: Rainwater, wastewater, or sewage containing solids with diameters allowed by the impeller (25mm to 45mm), chemically neutral and non-flammable liquids.
Maximum liquid temperature: 40°C
Minimum pumping level: 10 cm above the pump body
Maximum liquid density: Not greater than 1100 kg/m³
CONSTRUCTION:
Motor housing, motor body, pump body, and impeller: Cast iron G20
Motor shaft: AISI 416 stainless steel
Mechanical seal: Aluminum / Silicon Carbide
O-ring: NBR
ELECTRIC MOTOR:
2-pole electric motor immersed in special non-toxic dielectric oil for improved cooling
Protection rating: IP68
Insulation class: F
Voltage:
Single-phase: 230 V, 50 Hz, with thermal protection
Three-phase: 230/400 V, 50 Hz
The motor is cooled by the same liquid in which the pump is submerged
Power range: From 0.37 kW to 2.2 kW
EQUIPMENT:
Supplied with 10-meter H07 RN-F cable and Schuko plug
(5-meter cable for 0.5 HP pumps)
Three-phase versions are supplied with free cable ends
APPLICATIONS:
Domestic use
Industrial use